CVIEW-PFC Custom Gas Fireplace
Part No. XG0706
f i r e f e a t u r e
C-View fireplace:
The fireplace may be installed in any location that maintains proper
clearances to air conditioning ducts, electrical wiring and plumbing.
Safety, as well as efficiency of operation, must be considered when
selecting the fireplace location. Try to select a location that does not
interfere with room traffic, has adequate ventilation, and offers an
accessible pathway for vent installation. Refer to Vent Installation Sec-
tion for more information.
The fireplace dimensions are shown below and on the following page:
Figure 1. Fireplace dimensions.
WARNING!
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of the
appliance.
Front View
Installation
Figure 1a. Fireplace dimensions. (Contact the manufacturer for all
dimensions for models C520 through C720).
Figure 2. Air Intake dimensions. (Contact the manufacturer for all
dimensions for models C520 through C720).
Clearances
All building materials that are shaded in Figure 3 must be non-com-
bustible materials. The C-View-PFC must also maintain the following
clearances.
* See Instructions on page 4
** See Instructions on page 4
Unprotected combustible walls which are perpendicular to the fireplace
opening, must not be closer to the fireplace than the described in
Figure 7.
Note: Intake air for combustion of the C-View system, may originate
from within or from the exterior of the structure.
For installations where the combustion air intake ducts are not con-
nected to the exterior of the structure ensure there is adequate fresh
air in the interior space.
To operate efficiently, C-View gas fireplaces (with glass doors) require
80CFM per. 10,000 BTU's. Open face units require the specified
100CFM per. 10,000BTU of fresh air to operate properly.
Top of 90 Elbow (BV) 1"
Top of 90 Elbow (CV) 3"
Vent 1"
Sides 2"
Back 2"
Mantel(s)* 12"
Door**
1
/4"
Top 24"
Floor 0"
A
J
E
B
K
N
D
Exhaust
Intake Air
Optional
Intake
E
P
D
C
Side View
A
B C D
E F G H I J
K L M N
C420 54 56
26
N/A N/A N/A N/A
C520 N/A N/A
N/A
N/A N/A N/A N/A
C620
C720
C820
C-View-PFC Fireplace Dimensions
N/A
N/A
24
10
24
N/A
15
3
/
8
N/A
N/A
N/A
N/A
N/A
8
N/A
N/A N/A
N/A
N/A N/A N/A N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A
N/A
N/A N/A N/A N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
114 76
56
N/A N/A N/A N/A
36
8
42
17
N/A
N/A
18
5
8
/
5
8
/
3
4
/
C-View-PRC Air Intake Dimensions
O Qty of Vent s
P Dia. of V
ents
C420 2
C520
C620
C720
C820
3
Air Intake in/sq
Call
Call
Call
Call
Call
7
1
/
8
Bottom6
7
/
8
Rear
N/A
7
1
/
8
Bottom6
7
/
8
Rear
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A