Page 22
L52DF-ST* Indoor Gas Fireplace
XG0811 -100511.1
General
Have the replace and installation inspected yearly. The
inspection must include, but is not limited to, the following:
A visual check of the entire vent system and termination.
An inspection of the explosion relief appers and the door
gaskets to ensure a proper seal.
An inspection of the burner, vent run, and primary air open-
ings.
An inspection of the gas valve, gas components, and pilot
ame. For your convenience a 1/8" manifold pressure tap is
supplied on the gas valve for a test gauge connection.
Inspection of all optional equipment; fans, thermostats, etc.
For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For Propane Gas this appliance requires a minimum inlet pres-
sure of 11" W.C. and a manifold pressure of 10" W.C.
Always keep the replace area clear and free of combustible
materials, as well as gasoline and other ammable vapors and
liquids.
Do not use this appliance if any part has been under water. Imme-
diately call a qualied service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.
Cleaning
When the replace is rst activated, there may be some smoking and
a visible lm may be left on the glass. This is a normal condition, and
is the result of burning of protective coatings on new metal.
Glass must be cleaned periodically to remove any lm (which is
a normal by-product of combustion) which may be visible. Film
can easily be removed by removing the door, as shown on Page
19. Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.
Silicone seals on inner door during initial ring will "off gas", leav-
ing a visual deposit of a white substance on combustion chamber
walls. This can easily be removed from the chamber walls using
normal household products.
Use a vacuum cleaner or whisk broom to keep the control com-
partment, burner, and rebox free from dust and lint.
Clean the primary air openings from lint, embers, dust, etc.
Hi-Lo Burner Adjustment: (SIT Nova 820).
The L52DF-ST* is equipped with an adjustable burner, allowing you
to raise or lower the ames. To adjust the ames, locate the black
knob marked 'Hi-Lo', in the centre of the gas control valve (See
Figure 19).
To raise the ame height, turn the black knob (located behind
the lower control compartment) counter-clockwise.
To lower the ame height, turn clockwise.
Figure 19. 'Hi-Lo' Adjustment on the SIT Nova 820 gas valve,
Hi-Lo Burner Adjustment: (SIT Proame).
The L52DF-ST* is equipped with an adjustable burner, allowing you
to raise or lower the ames. To adjust the ames, locate the black
knob marked 'Hi-Lo', in the centre of the gas control valve (See
Figure 20).
To raise the ame height, turn the black knob (located behind
the lower control compartment) counter-clockwise.
To lower the ame height, turn clockwise.
Figure 20. 'Hi-Lo' Adjustment on the SIT Proame gas valve.
Manifold Pressure
Test Connection
Pilot Adjustment Screw
Hi Lo Adjustment
Inlet Pressure
Test Connection
Pilot Burner Adjustment.
1. Locate Pilot Adjustment Screw. (See gure 19 or 20.)
2. Adjust pilot screw to provide properly sized ame as shown.
3. After installing or servicing, leak test with a soap solution with
main burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.
Manifold Pressure
Test Connection
Wall Switch
Power
Generator
Pilot Adjustment Screw
Inl
e
t Pr
essu
r
e
'Hi-Lo' Adjustment Knob
Gas Control Knob
(Shown in “Pilot” position)
Maintenance