Montigo R720 Instruction Manual

Browse online or download Instruction Manual for Fireplaces Montigo R720. Montigo R720 Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
®
C US
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
DANGER
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
CAUTION
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
WARNING
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
NOTICE
IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
DANGER
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
XG0772 100614
R720
R820
R-Series
Indoor
Resi
dential
Fireplace
Installation & Maintenance Manual
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - XG0772 100614

Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248®C USRead and understand this manual. Improper ins

Page 2 - Table of Contents

Place the Fireplace on the platform and install the Vent pipe, and Power Vent module� Next, connect the Gas line, and provide a gas service shut-off v

Page 3 - Introduction

Figure 5. Completed back frame Fireplace installationBack framing the Fireplace NOTE: Maintain a 1" clearance around the throat (projection at t

Page 4

Picture of Non combustible HeaderRecessed Installation: This replace can be recessed into the oor to get the viewing area as low as possible.Mainta

Page 5

Figure 7. Flue cover and collar removal, Top Vented replaceFigure 7a. Flue cover and collar installation, Rear Vented replaceR720 & R820 Powe

Page 6

Figure 8. Factory installed Top Vent Pressure Sensing TubeFigure 8a. Supplied Rear Vent Pressure Sensing TubeFigure 9. Removal of Top Vent air baf

Page 7

Figure 10. Straight Vertical, Top or Rear Vent, Roof mounted power vent. Figure 10a. Multi-Elbow, Top or Rear Vent, Roof mounted powe

Page 8

Figure 10b. Multi-Elbow with downward vent run, Top or Rear Vent, Roof mounted power vent. R720 & R820 Power Vent Indoor Gas Fir

Page 9

Figure 12. Straight Horizontal, Top or Rear Vent, Wall mounted ... power vent. Figure 12a. Multi-Elbow, Top or Rear Vent, Wall mou

Page 10 - Installation

D** Figure 12b. Multi-Elbow with downward vent run, Top or Rear Vent, Wall mounted power vent. Section 3-3-1: Installing Wall Moun

Page 11

The following components and associated Montigo part numbers are for installation of a roof or wall mounted Power Vent. Only use Montigo Vent Componen

Page 12

Page 2XG0772 - 100614Table of ContentsR720 & R820 Power Vent Indoor Gas FireplaceInstruction Manual ContentsSafety Alerts � � � � � � � � � � � �

Page 13

Section 3-5: Heat Shields Installing a Wall Mounted RHS102 Heat shieldThe RHS102 Heat shield must be used if vent pipe passes through a wall or ceili

Page 14

R720 & R820 Power Vent Indoor Gas FireplacePage 21XG0772 - 100614InstallationSection 4: WiringFigure 15. R720* / R820* Series Control Box / Powe

Page 15

Figure 15a. (Control Panel Overview)Figure 15b. R720* / R820* Control ModuleLeft-side View Right-side ViewFigure 15c. (Remote Switch Wire connection)

Page 16

115R1 R2 R3R1R2LightPVPlugPV Speed ControllerYellowYellowBlackBlueBlueBrownYellowBlueBlackWhiteWhite1234 5Combustion AirFlueGasWallSwitchOrangeWhiteBl

Page 17

Figure 17. Gas Inlet Supply location.Fuel TypeVerify that your replace is compatible with your available gas type. Natural Gas or Propane shown by &q

Page 18

Figure 18. LED Indicators If the red LED is illuminated (beside the fuse) you have power to the panel� If no LED, check fuse and replace with equall

Page 19

As shown in Figure 19; Install the supplied Non-combustible cement board to overlap the new Horizontal & Vertical 2 x 4's, See Figure 5� Plac

Page 20

Figure 20� Combustible mantles and facings. (Not to scale)Finishing Around the FireplaceNon-combustible mantels and mouldings may be safely installed

Page 21

Step 3: Remove the trim from the bottom of the door as shown.Step 4: Remove the other side, as shown in Steps 1 - 3.Removing the door trim:Follow

Page 22

The R720* / R820* is supplied with glass restones. To install the restones remove the trim and door as shown in the previous section. Follow these i

Page 23

Congratulations on your purchase of a Montigo Fireplace� With over 30 years of experience, Montigo is committed to providing you with a gas replace

Page 24 - 1/2” MPT gas

STARTUP SEQUENCE:1) Turn the wall switch ON2) The combustion air switch relay will light up and the blowers will start. Within 10 seconds the

Page 25

General Have the replace and installation inspected yearly� The inspection must include, but is not limited to, the following: • A visual che

Page 26 - Clearance required for

R720 & R820 Power Vent Indoor Gas FireplacePage 32XG0772 - 100614AppendixAppendix A: Power Vent LocationsFor installation instructions on this te

Page 27

R720 & R820 Power Vent Indoor Gas FireplacePage 33XG0772 - 100614AppendixPVVEX510-300 Power Vent LocationsvvFIXEDCLOSEDOPERABLEFCBvvOPERABLEFIXED

Page 28

PVHEX510-300 Horizontal Power Vent DetailR720 & R820 Power Vent Indoor Gas FireplacePage 34XG0772 - 100614AppendixFor installation instructions o

Page 29

R720 & R820 Power Vent Indoor Gas FireplacePage 35XG0772 - 100614AppendixPVHEX510-300 Power Vent LocationsvvFIXEDCLOSEDOPERABLEFCBvvOPERABLEFIXED

Page 30 - Operation

R720 & R820 Power Vent Indoor Gas FireplacePage 36XG0772 - 100614AppendixPVHFL510-300 Horizontal Power Vent DetailFront ViewEaves / Overhang Wal

Page 31 - Maintenance

R720 & R820 Power Vent Indoor Gas FireplacePage 37XG0772 - 100614AppendixPVHFL510-300 Power Vent LocationsvvFIXEDCLOSEDOPERABLEFCBvvOPERABLEFIXED

Page 32 - Not Acceptable

The WarrantyThe Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the M

Page 33 - Appendix

Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.

Page 34

Installation and repairs should be done by an authorized gas fireplace service technician. The appliance should be inspected before use and at least a

Page 35

XG0772 -100614R720 - R820Single Sided Gas Fireplace

Page 36

Introduction to the R-Series Fireplace: The complete system will require a rebox, a power vent module, an electrical control panel, and a vent system

Page 37

Section 1: Product DimensionsFront ViewFigure 1� R720* Fireplace dimensions (Tolerance ± ⅛").Top ViewSide ViewGas InletCombustion Air Switch Sen

Page 38

Figure 1a� R820* Fireplace dimensions (Tolerance ± ⅛").Front ViewSide ViewTop View 40 1/16" 18" 108 11/16" 97 1/8"

Page 39 - Amendment

Frame in the enclosure for the unit with framing materials, see Figure 3.NOTE: When constructing the framed opening, please ensure there is access to

Page 40 - R720 - R820

Figure 3. Fireplace installation, (Rough Frame-In dimensions). Framing DimensionsModel Q R UR-Series R720* 101" 46"**23"†R-Series R820

Comments to this Manuals

No comments