Appendix A - Termination Locations
A = clearance to the termination frame above grade, veranda, porch, deck,
or balcony [16 inches (41 cm) minimum]
B = clearance to door, or sides and top of window, that may be opened [16
inches (41 cm) minimum for appliances 100 000 BTU/H (30kW)]
C = clearance to bottom of window that may be opened horizontally [36 inches
(92 cm) minimum for appliances 100 000 BTU/H (30kW)]
D = no clearance to permanently closed window when installed with approved
glass penetration termination
E = clearance to permanently closed window [16 inches 41 cm recommended
to prevent condensation on window]
F = vertical clearance to ventilated soft located above the termination within a
horizontal distance of 2 feet (61 cm) from the centreline of the termination
[22 inches (56 cm) minimum]
G = c l e a r a n c e t o u n v e n t i l a t e d s o f f i t [ 1 6 i n c h e s
( 4 1 c m ) m i n i m u m t o n o n - c o m b u s t i b l e s ]
[22 inches (56 cm) minimum to combustibles]
H = clearance to outside corner [9 inches (23 cm) minimum]
I = clearance to inside corner [12 inches (31 cm) minimum]
J = * not to be installed above a meter/regulator assembly within
40" (103 cm) horizontally from the centreline of the regulator
K = clearance to service regulator vent outlet [3 feet minimum in the United
States] [*6 feet (1.8 m) minimum in Canada]
L = clearance to non-mechanical air supply inlet to building or the combustion
air inlet to any other appliance [16 inches (41 cm) minimum for appliances
100 000 BTU/H (30kW)]
M = clearance to mechanical air supply inlet [*6 feet (1.8 m) minimum]
N =
clearance above paved sidewalk or a paved driveway located on public
property [*7 feet (2.1 m) minimum]
P = c le ar a nc e u n de r v e ra nd a , p or c h , de c k , or b a l co n y
[1 6 i n c h e s (4 1 cm ) mi ni mu m
to n on -c om bu s t i b l es ]
[22 inches (56 cm) minimum
to combustibles]
Q = clearance above a roof [24 inches (61 cm) minimum]
R = clearance to adjacent walls and neighboring buildings
[18 inches (46 cm) minimum]
S = c l e a r a n c e f r o m c o r n e r i n r e c e s s e d l o c a t i o n
[12 inches (31 cm) minimum]
T = m a x i m u m d e p t h i n r e c e s s e d l o c a t i o n
[48 inches (122 cm) minimum]
U = m i n im u m w id t h f or b a c k w al l of re ce s se d l o c a ti o n
[24 inches (61 cm) minimum]
V = no horizontal clearance between the frames of two terminations that
are level.
W = horizontal clearance between the frames of two terminations that are
not level. [36 inches (92 cm) minimum]
a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings
only permitted if veranda, porch, deck, or balcony has an open side that
is equal to or greater than the depth of the enclosed area
* as specied in CGA B149 Installation Codes. Note: local Codes or
Regulations may require different clearance.